Table 228 – Nortel Networks 1000 User Manual

Page 613

Advertising
background image

Configuration

613

Table 227
Trunk types - termination impedance and balance network (NT8D14BA, NT8D14BB) (cont’d.)

Balance network for loop lengths (Note 2)

Trunk types

Terminating
impedance
(Note 1)

0–915 m

(0–3000 ft)

915–1524 m

(3000–5000 ft)

> 1524 m

(> 5000 ft)

RAN: continuous
operation mode

600 or 900
hms

600 or 900 ohms

N/A

N/A

Paging

600 ohms

600 ohms

N/A

N/A

Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should
match the nominal impedance of the connecting equipment.

Note 2: The balance network of each trunk unit is software selectable between resistive 600 or
900 ohms or 3COM and jumper selectable between 3COM and 3CM2. Jumper selection for
3COM/3CM2 restriction does not apply to NT8D14BB.

Table 228
Cable loop resistance and loss

Cable loop resistance (ohms)

Cable loop loss (dB)

(nonloaded at 1kHz)

Cable length

22 AWG

24 AWG

26 AWG

22 AWG

24 AWG

26 AWG

915 m (3000 ft.)

97

155

251

0.9

1.2

1.5

1524 m (5000 ft.)

162

260

417

1.6

2.0

2.5

2225 m (7300 ft.)

236

378

609

2.3

3.0

3.7

3566 m (11700 ft.)

379

607

977

3.7

4.8

6.0

5639 m (18500 ft.)

600

960

1544

5.9

7.6

9.4

The trunk type, terminating impedance, and balance network are selected
by making service change entries in the Trunk Administration program LD
14.

Refer to

Table 231 "Trunk types - termination impedance and balance

network (NT8D14BA, NT8D14BB)" (page 615)

to select the proper values

for the trunk type and loop length being employed.

Refer to Meridian 1 Software Input/Output Reference — Administration
(NN43001-611) for LD 14 service change instructions.

Before the appropriate balance network can be selected, the loop length
between the near-end (Meridian 1) and the far-end (a Central Office, for
example) must be known. To assist in determining loop length, some
typical resistance and loss values for the most common cable lengths
are given in

Table 232 "Cable loop resistance and loss" (page 616)

, for

comparison with values obtained from actual measurements.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.