Nortel Networks 1000 User Manual

Page 492

Advertising
background image

492

NT8D14 Universal Trunk card

In Meridian 1 Option 11C systems the NT8D14 Universal Trunk Card is
installed in slots 1 through 10 of the Main cabinet, or in slots 11 through 50
in the Expansion cabinets.

When the card is installed, the red Light Emitting Diode (LED) on
the faceplate flashes as the self-test runs. If the self-test completes
successfully, the card is automatically enabled (if it is configured in
software) and the LED goes out. If the self-test fails, the LED lights
steadily and remains lit. The LED also turns on and remains lit if one or
more units on the card becomes disabled after the card is operating.

Each unit on the card connects to the backplane through an 80-pin
connector, the backplane is cabled to the Input/Output (I/O) panel, and the
I/O panel is cabled to the cross-connect terminal.

At the cross-connect terminal, each unit connects to external apparatus,
such as Central Office facilities or recorded announcement equipment.
Each unit connects to external apparatus by tip and ring leads which carry
voice, ringing, tone signaling, and battery.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising