Ds-1 carrier interface, Transmitter – Nortel Networks 1000 User Manual

Page 773

Advertising
background image

Architecture

773

On the NTAK09 use switch 1, position 1 to select either the D-channel
feature or the DPNSS feature, as follows:

OFF = D-channel

ON = DPNSS (U.K.)

DS-1 Carrier interface

Transmitter

The transmitter takes the binary data (dual unipolar) from the PCM
transceiver and produces bipolar pulses for transmission to the external
digital facility. The DS1 transmit equalizer enables the cabling distance
to extend from the card to the DSX-1 or LD-1. Equalizers are switch
selectable through dip-switches. The settings are shown in

Table 323

"NTAK09 switch settings" (page 773)

.

Table 323
NTAK09 switch settings

Switch Setting

Distance to Digital Cross-Connect

1

DCH F/W

2

(LEN 0)

3

(LEN 1)

4

(LEN 2)

0 - 133 feet

Off

Off

Off

On

133 - 266 feet

Off

On

On

Off

266 - 399 feet

Off

Off

On

Off

399 - 533 feet

Off

On

Off

Off

533 - 655 feet

Off

Off

Off

Off

The transmitter takes the binary data (dual unipolar) from the PCM
transceiver and produces bipolar pulses for transmission to the external
digital facility. The DS1 transmit equalizer allows the cabling distance to
be extended from the card to the DSX-1 or LD-1. Equalizers are switch
selectable through dip-switches and the settings are as shown below.

Table 324
NTAK09 switch settings

Switch Setting

Distance to Digital Cross-Connect

1

DCH F/W

2

(LEN 0)

3

(LEN 1)

4

(LEN 2)

0 - 133 feet

Off

Off

Off

On

133 - 266 feet

Off

On

On

Off

266 - 399 feet

Off

Off

On

Off

399 - 533 feet

Off

On

Off

Off

533 - 655 feet

Off

Off

Off

Off

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising