Nortel Networks 1000 User Manual

Page 184

Advertising
background image

184

NT5D11 and NT5D14 Lineside T1 Interface cards

Table 73
Lineside T1 card-T1 Switch 1 (S1) dip switch settings (cont’d.)

Dip Switch

Number

Characteristic

Selection

3–6

XPEC Address for the Lineside T1 card

See

Table 74 "Lineside T1

card - XPEC address dip
switch settings (Switch S1,
positions 3 - 6)" (page 184)

7

Not Used

Leave Off

8

Reserved for SL-100 use

Leave Off

Table 74
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6)

XPEC

Address

S1 Switch
Position 3

S1 Switch
Position 4

S1 Switch
Position 5

S1 Switch
Position 6

00

Off

Off

Off

Off

01

Off

Off

Off

On

02

Off

Off

On

Off

03

Off

Off

On

On

04

Off

On

Off

Off

05

Off

On

Off

On

06

Off

On

On

Off

07

Off

On

On

On

08

On

Off

Off

Off

09

On

Off

Off

On

10

On

Off

On

Off

11

On

Off

On

On

12

On

On

Off

Off

13

On

On

Off

On

14

On

On

On

Off

15

On

On

On

On

Table 75
Lineside T1 card - T1 Switch 2 (S2) dip switch settings

Dip Switch

Number

Characteristic

Selection

1

T1 framing

On = D4
Off = ESF

2

T1 Coding

On = AMI
Off = B8ZS

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.