NT8D09 Analog Message Waiting Line card

direct reporting of digit dialed (500-type telephones) by collecting dial
pulses

connection of –150 V dc at 1 Hz to activate message waiting lamps

lamp status detection

disabling and enabling of selected units for maintenance

Card interfaces

The analog message waiting line card passes voice and signaling data
over DS-30X loops and maintenance data over the card LAN link. These
interfaces are discussed in

“Intelligent Peripheral Equipment” (page 21)

.

Line interface units

The analog message waiting line card contains 16 identical and
independently configurable line interface units (also referred to as circuits).
Each unit provides 600-ohm impedance matching and a balance network
in a signal transformer/analog hybrid circuit. Circuits are also provided
in each unit to apply the ringing voltage onto the line synchronized
to the ringing current zero crossing. Signal detection circuits monitor
on-hook/off-hook status and switchhook flash detection. Four codecs are
provided to perform A/D and D/A conversion of line analog voiceband
signals to digital PCM signals. Each CODEC supports four line interface
units. The following features are common to all units on the card:

Transmission and reception of Scan and Signaling Device (SSD)
signaling messages over a DS30X signaling channel in A10 format.

Loopback of SSD messages and pulse code modulation (PCM) signals
for diagnostic purposes.

Correct initialization of all features, as configured in software, at
power-up.

Direct reporting of digits dialed (500 telephones) by collecting dial
pulses.

Connection of –150 V dc at 1 Hz to activate message waiting lamps
in two telephones in parallel. The two telephones must be the same
type or the neon series resistor in each telephone must be 54 K ohms
or greater.

Lamp status detection (does not detect a failure of either lamp when
operating in parallel).

Disabling and enabling of selected units for maintenance.

40 mA to telephones with short circuit protection.