Nortel Networks 1000 User Manual

Page 483

Advertising
background image

483

.

NT8D14 Universal Trunk card

Contents

This section contains information on the following topics:

“Introduction” (page 483)

“Physical description” (page 488)

“Functional description” (page 493)

“Operation” (page 501)

“Electrical specifications” (page 592)

“Connector pin assignments” (page 602)

“Configuration” (page 606)

“Applications” (page 627)

Introduction

Nortel is pleased to introduce the NT8D14CA Universal Trunk (XUT) card
as a replacement for the NT8D14BB card. The NT8D14CA has been
modified to add a longer loop capability for CAMA trunk applications.

The NT8D14CA comes equipped with a set of 2 jumpers for each hybrid
that should be set to the longer loop length (LL) when the trunk is used in
a CAMA application. The jumpers are numbered P35 to P50 and are set
to the shorter loop length (SL) position when it comes from the factory.
For each hybrid, both jumpers should be changed to the LL position only
if used as a CAMA trunk. Otherwise the jumpers should be left to the SL
position.

The NT8D14 Universal Trunk card interfaces eight analog trunk lines to
the system. Each trunk interface is independently configured by software
control using the Trunk Administration program LD 14.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.