Electrical specifications

693

Table 261 "Electrical characteristics" (page 692)

lists the electrical

characteristics of the trunk interface on the E and M Trunk card.

Table 262
Electrical characteristics of the E and M Trunk interface

Characteristic

4-wire trunk

2-wire trunk

Signaling range

Type I

150 ohms

Type II 300 ohms loop

Type I 150 ohms

Signaling type

Type I, Type II

Type I

Far-end battery

–42 to –52.5 V dc

–42 to –52.5 V dc

Near-end battery

–42.75 to –52.5 V dc

–42.75 to –52.5 V dc

Ground potential difference

±10 V dc

±10 V dc

Line leakage between E lead
and ground

ˇ

S20K ohms

³20K ohms

Effective loss

See pad table

(

Table 281 "Pad switching

algorithm" (page 711)

)

See pad table

(

Table 281 "Pad switching

algorithm" (page 711)

)

Terminating impedance

600 ohms

600 ohms

Balance impedance

N/A

600 ohms

Power requirements

Table 263 "Power requirements" (page 693)

lists the power requirements

for the E and M Trunk card.

Table 263
Power requirements

Voltage

Tolerance

Max current

+15.0 V dc

±5%

200 mA

–15.0 V dc

±5%

200 mA

+8.5 V dc

±2%

200 mA

–48.0 V dc

±5 %

415 mA

Table 264 "Power requirements" (page 693)

lists the power requirements

for the E and M Trunk card.

Table 264
Power requirements

Voltage

Tolerance

Max current

+15.0 V dc

±5%

200 mA

–15.0 V dc

±5%

200 mA

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.