Electrical specifications

469

Table 191
NT8D09 Analog Message Waiting Line Card technical summary (cont’d.)

Power input from backplane

-48 (can be as low as -42 for DC-powered systems), +15, -15,
+8.5 V and ringing voltage; also -150 V on analog message
waiting line card.

Insertion loss

6 dB + 1 dB at 1020 Hz
3.5 dB loss for analog to PCM,
2.5 dB loss for PCM to analog

Frequency response

The loss values in

Table 192 "Analog message waiting line card -

frequency response" (page 469)

are measured relative to the loss at 1

kHz.

Table 192
Analog message waiting line card - frequency response

Frequency (Hz)

Minimum (dB)

Maximum (dB)

60

20.0

200

0.0

5.0

300

–0.5

1.0

3000

–0.5

1.0

3200

–0.5

1.5

3400

0.0

3.0

Power requirements

Table 193 "Power requirements" (page 469)

provides the power

requirements for the NT8D09 Analog Message Waiting Line card.

Table 193
Power requirements

Voltage
(+/-)

Tolerance

Idle
current

Active
current

Max

+ 12.0 V dc

0.36 V dc

48 mA

0 mA

48
mA

+ 8.0 V dc

0.40 V dc

150 mA

8 mA

280
mA

–48.0 V dc

2.00 V dc

48 mA

40 mA

688
mA

Note 1: Each active ringing relay requires 10 mA of battery voltage.

Note 2: Reflects the current for ringing a single station set (or DN telephone).
There may be as many as five ringers on each line.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008