Operation

503

Figure 131
Loop start call states - incoming call from CO/FX/WATS

The alerting signal into the Meridian 1 is 20 Hz (nominal) ringing sent by
the CO. When an incoming call is answered, ringing is tripped when the
Meridian 1 places a low-resistance dc loop across the tip and ring leads
toward the CO. See

Figure 137 "Loop start call states - incoming call from

CO/FX/WATS" (page 510)

and

Figure 138 "Loop start call connection

sequence - incoming call from CO/FX/WATS" (page 511)

.

The alerting signal into the CS 1000 is 20 Hz (nominal) ringing sent by the
CO. When an incoming call is answered, ringing is tripped when the CS
1000 places a low-resistance dc loop across the tip and ring leads toward
the CO. See

Figure 133 "Loop start call states - incoming call" (page

505)

and

Figure 134 "Loop start call connection sequence - incoming call"

(page 506)

.

Nortel Communication Server 1000