Ring ground switches, Dch mode and address select switches – Nortel Networks 1000 User Manual

Page 84

Advertising
background image

84

Option settings

A set of four DIP switches provides selection among three values for
receiver impedance. Use SW8 for Trunk 0; use SW14 for Trunk 1 (see

Table 17 "Trunk interface impedance switch settings" (page 84)

).

Table 17
Trunk interface impedance switch settings

Description

SW8/SW14 Switch Settings

75

off

off

on

off

100

on

off

off

on

120

off

off

off

on

Ring ground switches

A set of four DIP switches selects which Ring lines are connected to
ground (see

Table 18 "Ring ground switch settings" (page 84)

).

Table 18
Ring ground switch settings

Switch

Description

S2 switch setting

1

Trunk 0 Transmit

off - Ring line is not grounded

on- Ring line is grounded

2

Trunk 0 Receive

off - Ring line is not grounded

on - Ring line is grounded

3

Trunk 1 Transmit

off - Ring line is not grounded

on - Ring line is grounded

4

Trunk 1 Receive

off - Ring line is not grounded

on - Ring line is grounded

DCH mode and address select switches

One switch selects an on-board NTBK51AA D-Channel daughterboard
and an external MSDL/DCHI card. Four other switches provide the
daughterboard address (see

Table 19 "DCH mode and address select

switch settings" (page 84)

).

Table 19
DCH mode and address select switch settings

Swit

ch

Description

S3 Switch Setting

1-4

D-Channel daughterboard
Address

See the next table.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.