NT8D41BA Quad Serial Data Interface Paddle Board

Table 286
NT8D41BA baud rate switch settings

SW13 (port 1), SW10 (port 2),

SW11 (port 3), SW12 (port 4)

Baud rate

Baud Clock

(kHz)

1

2

3

4

150

2.40

on

off

on

on

300

4.80

on

on

off

on

600

9.60

on

off

off

on

1,200

19.20

on

on

on

off

2,400

38.40

on

off

on

off

4,800

76.80

on

on

off

off

9,600

153.60

on

off

off

off

19,200*

307.20

on

on

on

on

* For future use.

Table 287
NT8D41BA address switch settings

SW15

Port 1

Port 2

Switch settings

SW16

Port 3

Port 4

1*

2

+

3

4

5

6

7

8

0

1

E

X

off

off

off

off

off

off

Device

2

3

E

X

off

off

off

off

off

on

4

5

E

X

off

off

off

off

on

off

pair

6

7

E

X

off

off

off

off

on

on

8

9

E

X

off

off

off

on

off

off

addresses

10

11

E

X

off

off

off

on

off

on

12

13

E

X

off

off

off

on

on

off

14

15

E

X

off

off

off

on

on

on

* To enable ports 1 and 2, set SW15 position 1 to ON. To enable ports 3 and 4, set SW16
position 1 to ON.

+

For each X, the setting for this switch makes no difference, because it is not used.

Address

Switch SW15 or SW16 and logic on the card always address the four
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 14 and 15.
The settings for both switches are shown in

Table 288 "NT8D41BA

address switch settings" (page 727)

. To avoid system problems,

switches SW15 and SW16 must not be configured identically.

Figure 246

"NT8D41BA QSDI paddle board" (page 723)

displays SW15 and SW16.