background image

Maintenance

403

Figure 105
MSDL states

A newly configured MSDL automatically enters the manually disabled
state. An operating MSDL can be manually disabled by issuing the

DIS

MSDL x

command in LD 37 (step 1 in

Figure 105 "MSDL states" (page

403)

).

Entering the

DIS MSDL x

command in LD 37 moves the card to manually

disabled status and stops all system communication with the card (step 5
in

Figure 105 "MSDL states" (page 403)

).

Manually enabled

When the card has been manually disabled, re-enable it with the

ENL

MSDL x

command in LD 37 (step 2 in

Figure 105 "MSDL states" (page

403)

).

System disabled

When the system disables the MSDL card (step 4 in

Figure 105 "MSDL

states" (page 403)

), it continues to communicate and attempt maintenance

procedures on the card. To stop all system communication with the
card, enter

DIS MSDL x

to disable it (step 5 in

Figure 105 "MSDL states"

Nortel Communication Server 1000