Table 65
Lineside T1 card LED operation

LED

OPERATION

STATUS

Line card

RED ALARM

T1 near end

YELLOW ALARM

T1 far end

MAINT

Maintenance

The STATUS LED indicates that the Lineside T1 card has successfully
passed its self test, and is functional. When the card is installed, this LED
remains lit for two to five seconds as the self-test runs. If the self-test
completes successfully, the LED flashes three times and remains lit. When
the card is configured and enabled in software, the LED goes out. If the
LED flashes continuously, or remains weakly lit, replace the card.