Electrical specifications – Nortel Networks 1000 User Manual

Page 691

Advertising
background image

Electrical specifications

691

Table 258
DX signaling - incoming calls with originating party release on tandem connections (cont’d.)

Condition

Current in
signaling lead

State of trunk
detector

If no-answer supervision is enabled, CO end
disconnects

Current flow

Low

Originating end disconnects – network torn
down and trunk idled

No current flow

High

Note:

* – CO ground start: the trunk is idled and the network taken

down, but the incoming tie trunk is controlled by the originating end.

Electrical specifications

This section lists the electrical specifications for the E and M Trunk card.

This section lists the electrical specifications for the E and M Trunk card.

The electrical characteristics of all trunk circuits are provided in

Table 260

"Electrical characteristics of trunk cards" (page 692)

.

Table 259 "Electrical characteristics of E and M Trunk cards" (page
691)

lists the electrical characteristics of the trunk interface on the E and M

Trunk card.

Table 259
Electrical characteristics of E and M Trunk cards

Characteristic

4-wire trunk

2-wire trunk

Signaling range

Type I#160;#160; 150 ohms
#160;#160; #160;#160; Type
II#160;#160; 300 ohms loop

Type I#160;#160; 150 ohms

Signaling type

Type I, Type II

Type I

Far-end battery

–42 to –52.5 V dc

–42 to –52.5 V dc

Near-end battery

–42.75 to –52.5 V dc

–42.75 to –52.5 V dc

Ground potential difference

±10 V dc

±10 V dc

Line leakage between E lead
and ground

ˇ

S20K

3

/

4

ˇ

S20K

3

/

4

Effective loss

See pad table (

Table 280 "Pad

switching algorithm" (page
709)

)

See pad table (

Table 280 "Pad

switching algorithm" (page
709)

)

Terminating impedance

600 ohms

600 ohms

Balance impedance

N/A

600 ohms

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.