Nt8d21 ringing generator ac, Nt8d22 system monitor – Nortel Networks 1000 User Manual

Page 94

Advertising
background image

94

Option settings

Companding law

Jumper at J3

4.5 db

on

on

off

3 db

on

off

off

0 db

off

on

off

0 db

off

off

off

Note: Set position 4 to ON to disable the warning tone option. When the warning tone is enabled,
select the warning tone level as shown below.

Level

Jumper at J2

24 db

connect pins 1 and 2

30 db

connect pins 2 and 3

NT8D21 Ringing Generator AC

Settings

Frequency

Amplitude

P1

P2

P3

20 Hz

86 V ac

open

open

2–5

8–11

25 Hz

70 V ac

open

1–4

7–10

open

25 Hz

80 V ac

open

3–6

9–12

open

25 Hz

86 V ac

open

2–5

8–11

open

50 Hz

70 V ac

1–4

7–10

open

open

50 Hz

80 V ac

3–6

9–12

open

open

NT8D22 System Monitor

The master system monitor, located in the column with CP 0, must be
numbered 0. Slave system monitors are numbered from 1 to 63.

For examples of system monitor option settings in basic configurations,
see "Sample settings for NT8D22 System Monitors."

Configure the system monitor in Remote Peripheral Equipment (RPE)
columns as slaves. There is no serial connection between RPE columns.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.