Software service changes, Applications – Nortel Networks 1000 User Manual

Page 737

Advertising
background image

Applications

737

Table 294
NT8D41BA DTE/DCE/Fiber switch settings (cont’d.)

Port 1 — SW 3

Port 1 —SW 2

Mode

1

2

3

4

5

6

1

2

3

4

5

6

NT1P61 (Fiber)

on on on on on of

f

on on on of

f

on of

f

Port 3 — SW 7

Port 3— SW 6

DTE (terminal)

on on on of

f

on of

f

of

f

on of

f

on of

f

on

DCE (modem)

of

f

of

f

of

f

on of

f

on on of

f

on of

f

on of

f

NT1P61 (Fiber)

on on on on on of

f

on on on of

f

on of

f

Port 4 — SW 9

Port 4 — SW 8

DTE (terminal)

on on on of

f

on of

f

of

f

on of

f

on of

f

on

DCE (modem)

of

f

of

f

of

f

on of

f

on on of

f

on of

f

on of

f

NT1P61 (Fiber)

on on on on on of

f

on on on of

f

on of

f

Software service changes

Once the NT8D841BA QSDI paddle board has been installed in the
system, the system software needs to be configured to recognize it, using
the Configuration Record program LD 17. Instructions for running this
program are found in Software Input/Output Reference — Administration
(NN43001-611).

Some of the prompts that are commonly used when running the
Configuration Record program LD 17 are shown in

Table 12 "TDS tone

tests" (page 77)

. These parameters must be set for each port if both ports

are being used.

Applications

The NT8D41BA Quad Serial Data Interface paddle board is used to
connect the Meridian 1 switch to a variety of communications devices,
printers, and peripherals. Any RS-232-C compatible device can be
connected to either of the card’s two serial ports.

The standard application for the paddle board is to connect the Meridian
1 switch to the system console. This can be either a direct connection
if the console is located near the switch, or through a modem for remote
maintenance.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising