Card control functions – Nortel Networks 1000 User Manual

Page 430

Advertising
background image

430

NT8D02 and NTDK16 Digital Line cards

Each digital telephone line terminates on the digital line card at a TCM
loop interface circuit. The circuit provides transformer coupling and foreign
voltage protection between the TCM loop and the digital line interface
circuit. It also provides battery voltage for the digital telephone.

To prevent undesirable side effects from occurring when the TCM loop
interface cannot provide the proper signals on the digital phone line, the
card microcontroller can remove the ±15 V dc power supply from the
TCM loop interfaces. This happens when either the microcontroller gets
a command from the NT8D01 controller card to shut down the channel
or the digital line card detects a loss of the 1 KHz frame synchronization
signal. The ±15 V dc power supply signal is removed from all 16 TCM loop
interface units at the same time.

Each TCM loop interface circuit can service loops up to 3500 ft. in length
when using 24-gauge wire. They allow for a maximum AC signal loss of
15.5 dB at 256 KHz and a maximum DC loop resistance of 210 ohms.

Each digital telephone line terminates on the NT8D02 Digital Line Card
at a TCM loop interface circuit. The circuit provides transformer coupling
and foreign voltage protection between the TCM loop and the digital line
interface circuit. It also provides battery voltage for the digital telephone.

To prevent undesirable side effects from occurring when the TCM loop
interface cannot provide the proper signals on the digital phone line, the
card microcontroller can remove the ±15 V dc power supply from the
TCM loop interfaces. This happens when either the microcontroller gets
a command from the NT8D01 controller card to shut down the channel,
or the digital line card detects a loss of the 1 KHz frame synchronization
signal. The ±15 V dc power supply signal is removed from all 16 TCM loop
interface units at the same time.

Each TCM loop interface circuit can service loops up to 3500 ft. in length
when using 24-gauge wire. They support a maximum ac signal loss of
15.5 dB at 256 KHz and a maximum dc loop resistance of 210 ohms.

Card control functions

Control functions are provided by a microcontroller and a Card LAN link on
the digital line card. A sanity timer is provided to automatically reset the
card if the microcontroller stops functioning for any reason.

Control functions are provided by a microcontroller and a Card LAN link on
the digital line card. A sanity timer is provided to automatically reset the
card if the microcontroller stops functioning for any reason.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.

Advertising