NT8D41BA Quad Serial Data Interface Paddle Board

Figure 247
NT8D41BA QSDI paddle board block diagram

System considerations

For CS 1000 4.5 and 5.0, in dual-processor systems, the 2 card slots
on the back of a CoreNet shelf supporting CP PII and CP PIV function
regardless of which CPU is active. On Release 5.0 only the CP PII and
CP PIV are supported. In Options 61C and 81C, CS 1000SG, and CS
1000MG, four NT8D41BB can be provisioned for a total of 16 SDI ports.
One port is used for power monitoring, leaving 15 for customer use.

Connector pin assignments

The RS-232-C signals for port 1 through port 4 are brought out on
connector J1 through J4 respectively. The pinouts for each port are
identical to those for each of the other three ports.

Table 285 "Connectors

J1, J2, J3, and J4 pin assignments" (page 725)

shows the pin assignment

that applies to each connector.