400

NT6D80 MSDL card

Cable installation

When the MSDL card is installed, connect the cables to the equipment
required for the selected operation.

PRI trunk connections

D-channel operations require connections between the MSDL and
a PRI trunk card. Refer to ISDN Primary Rate Interface: Features
(NN43001-569) for a complete discussion of PRI and D-channels.

Procedure 18
Cabling the MSDL card to the PRI card

Step

Action

The following steps explain the procedure for cable connection:

1

Identify the MSDL and the PRI cards to be linked.

2

Select the appropriate length cable for the distance between the
MSDL and the PRI card.

3

Plug the 26-pin SCSI II male connector end of a cable into the
appropriate MSDL port.

4

Route the cable through cable troughs, if necessary, to the
appropriate PRI card.

5

Plug the DB15 male connector end of the cable into the J5 DB15
female connector on the PRI card.

6

Secure the connections in place with their fasteners.

7

Repeat steps 1 through 6 for each connection.

--End--

I/O panel connections

Operations aside from PRI require cable connections to the I/O panel.

Procedure 19
Cabling the MSDL card to the I/O panel

Step

Action

The following steps explain the procedure for cable connection:

1

Identify the MSDL card and the I/O panel connector to be linked.

2

Using the NTND27AB cable, plug the 26-pin SCSI II male
connector end of a cable into the appropriate MSDL port.

3

Route the cable to the rear of the module next to the I/O panel.

4

Plug the DB25 male connector end of a cable into a DB25
female connector at the back of the I/O panel.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008