NTDK20 Small System Controller card

Figure 263
NTDK99A single-port 100BaseT IP daughterboard

Table 395
Expansion daughterboards

Daughterboard

Number
of ports

Cable type

Max. distance between Call
Server and Media Gateway
systems

NTDK99 (used in
Media Gateway)

one

NTDK83 (used in
Call Server

two

Use the supplied
NTTK34AA UTP
CAT 5 RJ-45 2 m
cross-over cable
to connect the
Call Server and
Media Gateway
using the 100BaseT
daughterboards.

The NTTK34AA
cross-over cable must
be used if connecting
point-to-point.

Media Gateways can be located
up to 100 m (328 ft.) from
the Call Server if connected
point-to-point, or up to 40 km (24
miles) from the Call Server if a
third party converter is used to
convert to fiber.

Note:

If not connecting point-to-point, connect the Call Server and

Media Gateway using a straight-through Ethernet UTP Cat 5 cable.

Call Servers can be connected to Media Gateway in the following ways:

Nortel Communication Server 1000