CHAPTER 2: INSTALL ATION/CONFIGURATION

EPOS MOTOR MANAGEMENT SYSTEM- INSTRUCTION MANUAL

2.83

 

 

 

 

Tables below show the default configuration for all typicals.

 

 

 

Motor Starter Standard Configuration

EntelliPro ES3

 

Full-voltage

non-

reversing

Full-voltage

reversing

Star-delta

non-

reversing

Star-delta

reversing

Softstarter

Softstarter

reversing

Breaker

Dahlander

Pole-

changer

 

Actuator

Solenoid

valve

Feedback via contact Activated

Activated

Activated

Activated

N/A

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Feedback via current Activated

Activated

Activated

Activated

N/A

Activated

Activated

N/A

Activated

Activated

Activated

N/A

Direct Switch over without OFF command

N/A

Deactivated

N/A

N/A

N/A

Deactivated

N/A

Activated

Activated

Deactivated

N/A

Current depending YD Switch Over

N/A

N/A

Activated

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Soft Stop Timer

N/A

N/A

N/A

N/A

Deactivated

Deactivated

N/A

N/A

N/A

N/A

N/A

Bypass Control

N/A

N/A

N/A

N/A

Activated

Activated

N/A

N/A

N/A

N/A

N/A

External Soft Starter Fault

N/A

N/A

N/A

N/A

Activated

Activated

N/A

N/A

N/A

N/A

N/A

MCCB Tripped 2 Configuration (Alarm or

No-Alarm)

N/A

N/A

N/A

N/A

N/A

N/A

no alarm

N/A

N/A

N/A

N/A

Breaker Trip Reset from EntelliPro ES

N/A

N/A

N/A

N/A

N/A

N/A

Activated

N/A

N/A

N/A

N/A

MCCB Feedback

N/A

N/A

N/A

N/A

N/A

N/A

Activated

N/A

N/A

N/A

N/A

Torque Switch

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Disable

N/A

Switch OFF at Limit Switch

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Activated

N/A

Switch OFF at Current Threshold

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Deactivated

N/A

Switch OFF at Torque Switch

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Deactivated

N/A

Enable Modbus RTU Control

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable Profibus DP Class 2 Control

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable Hardwired Control

Disable

Disable

Disable

N/A

Disable

Disable

Disable

Disable

Disable

Disable

Disable

bit 1 - Class1 n bit 0r (n+1) bit

n bit

n bit

n bit

N/A

n bit

n bit

n bit

n bit

n bit

n bit

n bit

bit 2 - Level/Edge

Level

Level

Level

N/A

Level

Level

Level

Level

Level

Level

Level

bit 3 - Inverted OFF / Non-Inverted OFF

non

non

non

N/A

non

non

non

non

non

non

non

bit 1 - Hardwire n bit 0r (n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

N/A

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

bit 2 - Hardwire Level/Edge

Edge

Edge

Edge

N/A

Edge

Edge

Edge

Edge

Edge

Edge

Edge

Thermistor Line Broken/Shorted Supervision.

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Drawer Position Supervision

Deactivated

Deactivated

Deactivated

N/A

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Drawer Position 1 bit Modus / 2 bit Modbus

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Modbus Failure Detection

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

ATEX Activated

Deactivated

Deactivated

Deactivated

N/A

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

bit 5 - Remote OFF always valid

Deactivated

Deactivated

Deactivated

N/A

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

bit 6 - Block Local Switch ON

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Alarm Setting

 

 

 

 

 

Overload

Enable

Enable

Enable

N/A

Enable

Enable

Disable

Enable

Enable

Enable

Enable

Phase Loss

Enable

Enable

Enable

N/A

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Ground Fault

Enable

Enable

Enable

N/A

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Unbalance Load

Enable

Enable

Enable

N/A

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Thermsitor

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Emergency Stop

Enable

Enable

Enable

N/A

Enable

Enable

Disable

Enable

Enable

Enable

Enable

Limit Switch

Disable

Disable

Disable

N/A

Disable

Disable

Disable

Disable

Disable

Enable

Enable

Safety Circuit

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Main Circuit

Enable

Enable

Enable

N/A

Enable

Disable

Enable

Enable

Enable

Enable

Enable

Control Circuit

Enable

Enable

Disable

N/A

Disable

Disable

Disable

Disable

Enable

Disable

Disable

Switch Position

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Underload Current

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Overload Current

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Enable

Enable

External Supervisory

Enable

Enable

Enable

N/A

Enable

Enable

Enable

Enable

Enable

Disable

Enable

Long Start Time

Enable

Enable

Enable

N/A

Enable Enable

Enable

e

Enable

Enable

Enable

i

Disable

Input Mapping

 

 

 

 

 

Input 99 Mapping

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

N/A

Contactor 1

Feedback

Contactor 1

Feedback

MCCB ON
Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Input 99 High/low Activation

Active High

Active High

Active High

N/A

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Input 98 Mapping

External

Supervision

Contactor 2

Feedback

Contactor 2

Feedback

N/A

Main Circuit

Feedback

Contactor 2

Feedback

Breaker

Ready to

Switch ON

Contactor 2

Feedback

Contactor 2

Feedback

Contactor 2

Feedback

Main Circuit

Feedback

Input 98 High/Low activation

Active Low

Active High

Active High

N/A

Active Low

Active High

Active High

Active High

Active High

Active High

Active Low