7 testing and certification – GE Industrial Solutions EntelliPro ES User Manual

Page 22

Advertising
background image

CHAPTER 1: INTR ODUCTION

1.14

EP OS MOTOR MANAGEMENT SYSTEM – INSTRUCTION MANUAL

 

 

 

1.2.7 Testing and certification

 


Test Reference Standard Test Level

 

Dielectric voltage withstands ...................................

.......1.5kV

Impulse voltage withstand ..............................................EN60255-5

Electrostatic discharge.......................................................EN61000-4-2/IEC60255-22-2 Level 4

 

RF immunity ............................................................................EN61000-4-3/IEC60255-22-3 Level 3

 

Fast transient disturbance ...............................................EN61000-4-4/IEC60255-22-4 Class A

Surge immunity ................. ..................................................EN61000-4-5/IEC60255-22-5 Level 3

Conducted RF immunity ....................................................EN61000-4-6/IEC60255-22-6 Level 3

 

Radiated and conducted emissions.............................CISPR11 /CISPR22/ IEC60255-25 Class A

Sinusoidal vibration ...........................................................IEC60255-21-1 Class 1

Voltage dip and interruption ..........................................IEC61000-4-11 0, 40, 70% dips, 250/300 cycle interrupts

 

Harmonics ..................................................................

............IEC61000-4-13

 

Voltage ripple ........................................................................IEC61000-4-17 15% ripple

Environmental (cold)................................................. .........IEC60068-2-1 -25° C,

96 hrs

Environmental (dry heat) .................................................IEC60068- 2-2 70° C,

96 hrs

Relative humidity cyclic ...................................................IEC60068- 2-30 6-day variant 2

Short-circuit current*.........................................................IEC60947-5-1

 

ATEX certificati

o

Rated impulse withstand voltage ............................4kV

(when EntelliPro ES is not directly connected to the main voltage)

(when EntelliPro ES is directly connected to the main voltage)

Overvoltage category II according to IEC 60947-1 7.2.3.1 item 2) b)

Pollution degree...................................................................I

Overvoltage category III according to IEC 60947-1 7.2.3.1 item 2) b)

 

SIL1

 

Profibus certification

 

*CAUTION:

A maximum A7DQS or gl 10A fuse is required on motor relays.

Pper

Advertising