4 output specifications – GE Industrial Solutions EntelliPro ES User Manual

Page 20

Advertising
background image

CHAPTER 1: INTR ODUCTION

1.12

EP OS MOTOR MANAGEMENT SYSTEM – INSTRUCTION MANUAL

 

 

 

 

1.2.4 Output specifications

 

4 - 20 mA Output

 

Accuracy...................................................................................±1% from displayed RMS

 

Motor Contact Relays

Configuration..........................................................................electromechanical SPST

Contact material ...................................................................silver alloy

Operate time...........................................................................10ms

Minimum contact load .......................................................10mA at 5Vdc

Continuous current ..............................................................5A at 240Vac

/ 30Vdc

 


Resistive load capacity

 

Maximum switched power ...............................................150W or 1250VA

Maximum switched current .............................................5A

Maximum switched voltage.............................................150Vdc or 250Vac

 


Life expectancy

 

Mechanical ..............................................................................20 million operations

 

Electrical ..................................................................................100,000 operations at 5A, 30Vdc or 250Vac

 

Application category (for AC-15 and DC-13) ............5A/240VA – AC-15

2.5A / 24Vdc – DC-13

According to IEC-60947-5-1

Normal and Abnormal Conditions

A7DQS or gl 10Amps fuses required

 

Signal Relays

Configuration..........................................................................electromechanical SPST

Contact material ...................................................................silver alloy

Operate time...........................................................................10ms

Minimum contact load .......................................................10mA at 5Vdc

Continuous current ..............................................................3A at240Vac

 

Resistive load capacity

 

Maximum switched current .............................................3A

 

Maximum switched voltage.............................................150Vdc or 250Vac

 

Life expectancy

 

Mechanical ..............................................................................20 million operations

 

Electrical ..................................................................................100,000 operations at 5A, 30Vdc or 250Vac

 

Advertising