GE Industrial Solutions EntelliPro ES User Manual

Page 111

Advertising
background image

CHAPTER 2: INSTALL ATION/CONFIGURATION

2.86

EP OS MOTOR MANAGEMENT SYSTEM – INSTRUCTION MANUAL

 

 

 

 

 

 

Motor Starter Standard Configuration

EntelliPro ES5

 

Full-voltage

non-

reversing

Full-voltage

reversing

Star-delta

non-

reversing

Star-delta

reversing

Softstarter

Softstarter

reversing

Breaker

Dahlander

 

Polechanger

 

Actuator

Solenoid

Valve

Input 97 Mapping

Reset Alarm

Reset Alarm

Delta

Contactor
Feedback

Y Contactor

Feedback

Reset Alarm

Bypass

Contactor
Feedback

Breaker

Charged

Contactor Y

Feedback

Reset Alarm

External

Supervision

Drawer

Position Test

Input 97 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Input 96 Mapping

Drawer

Position Test

Drawer

Position Test

Drawer

Position Test

Delta

Contactor
Feedback

Up to Speed

Feedback

Up to Speed

Feedback

Tripped

Drawer

Position Test

Drawer

Position Test

Mode Switch

Local

Mode Switch

Local

Input 96 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active Low

Active High

Active High

Active High

Active High

Input 95 Mapping

Drawer

Position

Operation

Drawer

Position

Operation

Drawer

Position

Operation

Reset Alarm

fb starter

fault

fb starter

fault

Tripped 2

Drawer

Position

Operation

Drawer

Position

Operation

Mode Switch

Remote

Mode Switch

Remote

Input 95 High/low Activation

Active High

Active High

Active High

Active High

Active Low

Active Low

Active Low

Active High

Active High

Active High

Active High

Input 94 Mapping

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Main Circuit

Feedback

Input 94 High/low Activation

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Input 93 Mapping

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Control

Circuit

Feedback

Input 93 High/low Activation

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Input 11 Mapping

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

Cmd OFF

cmd close

Input 11 High/low Activation

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Input 12 Mapping

Cmd ON

Cmd ON

Right

Cmd ON

Cmd ON

Right

Cmd ON

Cmd ON

Right

Cmd ON

Cmd ON

slow

Cmd ON

slow

Cmd ON

Right

cmd open

Input 12 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Input 13 Mapping

Not Used

Cmd ON

Reverse

Reset Alarm

Cmd ON Left

Drawer

position Test

Cmd ON Left

Reset Alarm

Cmd ON fast

Cmd ON fast

Cmd ON Left

Reset Alarm

Input 13 High/low Activation

N/A

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Input 14 Mapping

External

Fault 1

External

Fault 1

External

Fault 1

External

Fault 1

External

Fault 1

External

Fault 1

External

Fault 1

External

Fault 1

External

Fault 1

fb torque

open

External

Fault 1

Input 14 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active Low

Active High

Input 15 Mapping

External

Supervision

External

Supervision

External

Supervision

External

Supervision

Drawer

position

Operation

External

Supervision

External

Supervision

Reset Alarm

External

Supervision

fb torque

close

External

Supervision

Input 15 High/low Activation

Active Low

Active Low

Active Low

Active Low

Active High

Active Low

Active Low

Active High

Active Low

Active Low

Active Low

Input 16 Mapping

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Emergency

Stop

Input 16 High/low Activation

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Input 17 Mapping

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Safety Circuit

Input 17 High/low Activation

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Active Low

Input 18 Mapping

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Mode Switch

Local

Limit Open

Feedback

Limit Open

Feedback

Input 18 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active Low

Active Low

Input 19 Mapping

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Mode Switch

Remote

Limit Close

Feedback

Limit Close

Feedback

Input 19 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active Low

Active Low

Relay Output Mapping

 

 

 

 

 

First Function Relay 42 Mapping

Contactor 1

Contactor 1

Contactor 1

Contactor 1

Contactor 1

Contactor 1

MCCB on

Contactor 1

Contactor 1

Contactor 1

Contactor 1

Second Function Relay 42 Mapping

None

None

None

None

None

None

None

None

None

None

None

 

 

 

 

 

 

First Function Relay 43 Mapping

ATEX

Redundancy

Output

Contactor 2

Contactor D

Contactor D

Bypass

Bypass

MCCB off

Contactor 2

Contactor 2

Contactor 2

Ready for

Switch on

Second Function Relay 43 Mapping

None

None

None

None

None

None

None

None

None

None

None

 

 

 

 

 

 

First Function Relay 45 Mapping

Warning

ATEX

Redundancy

Output

Contactor Y

Contactor 2

ATEX

Redundancy

Output

Left

Reset

Contactor Y

ATEX

Redundancy

Output

ATEX

Redundancy

Output

Warning

Second Function Relay 45 Mapping

Failure

(Output

Flashing)

None

None

None

None

None

None

None

None

None

Failure

(Output

Flashing)

First Function Relay 22 Mapping

Local

Local

ATEX

Redundancy

Output

ATEX

Redundancy

Output

Local

ATEX

Redundancy

Output

Local

ATEX

Redundancy

Output

Local

Local

Local

Second Function Relay 22 Mapping

None

None

None

None

None

None

None

None

None

None

None