CHAPTER 2: INSTALL ATION/CONFIGURATION

EPOS MOTOR MANAGEMENT SYSTEM- INSTRUCTION MANUAL

2.85

 

 

 

 

 

 

 

Motor Starter Standard Configuration

EntelliPro ES5

 

Full-voltage

non-

reversing

Full-voltage

reversing

Star-delta

non-

reversing

Star-delta

reversing

Softstarter

Softstarter

reversing

Breaker

Dahlander

 

Polechanger

 

Actuator

Solenoid

Valve

Feedback via contact

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Feedback via current

N/A

Activated

Activated

Activated

Activated

Activated

N/A

Activated

Activated

Activated

N/A

Direct Switch over without OFF

command

N/A

Deactivated

N/A

Deactivated

N/A

Deactivated

N/A

Activated

Activated

Deactivated

N/A

Current depending YD Switch Over

N/A

N/A

Activated

Activated

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Soft Stop Timer

N/A

N/A

N/A

N/A

Deactivated

Deactivated

N/A

N/A

N/A

N/A

N/A

Bypass Control

N/A

N/A

N/A

N/A

Activated

Activated

N/A

N/A

N/A

N/A

N/A

External Soft Starter Fault

N/A

N/A

N/A

N/A

Activated

Activated

N/A

N/A

N/A

N/A

N/A

MCCB Tripped 2 Configuration (Alarm

or No-Alarm)

N/A

N/A

N/A

N/A

N/A

N/A

No alarm

N/A

N/A

N/A

N/A

Breaker Trip Reset from EntelliPro ES

N/A

N/A

N/A

N/A

N/A

N/A

Activated

N/A

N/A

N/A

N/A

MCCB Feedback

N/A

N/A

N/A

N/A

N/A

N/A

Activated

N/A

N/A

N/A

N/A

Torque Switch

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Enable

N/A

Switch OFF at Limit Switch

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Activated

N/A

Switch OFF at Current Threshold

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Deactivated

N/A

Switch OFF at Torque Switch

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

Deactivated

N/A

Enable Modbus RTU Control

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable Profibus DP Class 2 Control

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable Hardwired Control

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

bit 1 - Class1 n bit 0r (n+1) bit

n bit

n bit

n bit

n bit

n bit

n bit

n bit

n bit

n bit

n bit

n bit

bit 2 - Level/Edge

Level

Level

Level

Level

Level

Level

Level

Level

Level

Level

Level

bit 3 - Inverted OFF / Non-Inverted

OFF

Non

Non

Non

Non

Non

Non

Non

Non

Non

Non

Non

bit 1 - Hardwire n bit 0r (n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

(n+1) bit

bit 2 - Hardwire Level/Edge

Edge

Edge

Edge

Edge

Edge

Edge

Edge

Edge

Edge

Edge

Edge

Thermistor Line Broken/Shorted

Supervision.

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Drawer Position Supervision

Activated

Activated

Activated

Deactivated

Activated

Deactivated

Deactivated

Activated

Activated

Deactivated

Activated

Drawer Position 1 bit Modus / 2 bit

Modbus

2 bit

2 bit

2 bit

N/A

2 bit

N/A

N/A

2 bit

2 bit

N/A

2 bit

Modbus Failure Detection

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

ATEX Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

Activated

bit 5 - Remote OFF always valid

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

Deactivated

bit 6 - Block Local Switch ON

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Alarm Setting

 

 

 

 

 

Overload

Enable

Enable

Enable

Enable

Enable

Enable

Disable

Enable

Enable

Enable

Enable

Phase Loss

Enable

Enable

Enable

Enable

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Ground Fault

Enable

Enable

Enable

Enable

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Unbalance Load

Enable

Enable

Enable

Enable

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Thermsitor

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Emergency Stop

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Limit Switch

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Disable

Enable

Enable

Safety Circuit

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Main Circuit

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Control Circuit

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Switch Position

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Underload Current

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Overload Current

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

External Supervisory

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Enable

Long Start Time

Enable

Enable

Enable

Enable

Enable

Enable

Disable

Enable

Enable

Enable

Disable

Input Mapping

 

 

 

 

 

Input 99 Mapping

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

MCCB ON

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Contactor 1

Feedback

Input 99 High/low Activation

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Input 98 Mapping

not used

Y Contactor

Feedback

Contactor 2

Feedback

Contactor 2

Feedback

Bypass

Feedback

Contactor 2

Feedback

Breaker

Ready to

Switch ON

Contactor 2

Feedback

Contactor 2

Feedback

Contactor 2

Feedback

Drawer

position Test

Input 98 High/Low activation

N/A

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High

Active High