Web Server Help Files Collection

Current values of tiltmeter data:

For each serial port (A, B, F), the following parameters are
returned:

Legacy D-File Support:

Data Output

This section consists of three pages, each of them listing a
category of output data delivered by the receiver.

Differential Messages:

Parameter

Designation

$PASHQ

Angular Displacement
North

Current value of angular displacement
(North), as delivered by the tiltmeter.

XDR

Angular displacement
East

Current value of angular displacement
(East) as delivered by the tiltmeter.

XDR

Temperature

Current value of temperature, as
delivered by the tiltmeter.

XDR

Parameter

Designation

$PASHQ

Process tiltmeter

Tells whether the receiver is allowed
to query the tiltmeter, if connected to
this port.

TLT

Baud Rate

Current value of baud rate used on
the port

PRT

Mode

Indicates whether the port is currently
an RS232 (232) or RS422 (422) serial
port. Only port A can be RS422 or
RS232. All the others are necessarily
RS232.

MDP

RTS/CTS

Indicates whether the handshaking
protocol is used (Enabled) or not (Dis-
abled) on this port.

CTS

Initialization String

String used by the receiver to initialize
the tiltmeter, if connected to this port.

TLT

Trigger String

String used by the receiver to query
the tiltmeter, if connected to this port.

TLT

Interval

Current value of time interval, in sec-
onds, used by the receiver to query
the tiltmeter, if connected to this port.

TLT

Parameter

Designation

$PASHQ

Legacy D-File Support

Indicates whether the legacy D-file is
supported (Yes) or not (No). In the lat-
ter case, only the G-file is supported.

RFT

Advertising