Relevant query command, See also, Function – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 435: Command format

Advertising
background image

421

Set Command Library

Parameters

Example

Making the falling edge active:

$PASHS,PHE,F*42

Relevant Query

Command

$PASHQ,PHE

See Also

$PASHS,NME,TTT

POP: Setting Internal Update Rate for Measurements and PVT

Function

This command allows you to set the updates rate used
internally in the measurements and position processing.

Command Format

Syntax

$PASHS,POP,d[*cc]

Parameters

Example

Setting the update rate to 10 Hz:

$PASHS,POP,20*17

Comments

• Outputting data at 20 Hz through $PASHS,NME,

$PASHS,ATM and $PASHS,RAW requires that the present
update rate stays at 20 Hz (default value).

Parameter

Description

Range

Default

c1

Active edge code:
• “R” for rising edge
• “F” for falling edge

R, F

R

*cc

Optional checksum

*00-*FF

Parameter

Description

Range

Default

d

Internal update rate, in Hz, for measure-
ments and PVT.

10, 20

20

*cc

Optional checksum

*00-*FF