328

Set Command Library

$PASHS,BDS,RT2,I1,OFF*OF

Relevant Query

Command

$PASHQ,BDS

See Also

$PASHS,DST

$PASHS,RTC,TYP

$PASHS,ATD,TYP

BEEP: Beeper Setup

Function

This command enables or disables the internal beeper.

Command Format

Syntax

$PASHS,BEEP,s1[,d2][*cc]

Parameters

Example

Disabling the beeper:

$PASHS,BEEP,OFF*04

Relevant Query

Command

$PASHQ,BEEP

BRD: Enabling/Disabling the RTC Bridge Function

Function

This command is used to control the RTC Bridge function. Its
use is required only in the receiver in charge of forwarding its

Parameter

Description

Range

Default

s1

Enables (ON) or disables (OFF) the beeper. ON, OFF ON

d2

Timeout, in seconds:
• 0: No timeout. If an alarm is activated, the

beeper will sound indefinitely until the
alarm is acknowledged.

• >0: If an alarm is activated, the beeper

will sound only for a limited period of time
(it will go out automatically at the end of
the specified timeout).

0-99

30

*cc

Optional checksum

*00-*FF

Advertising