Set Command Library

DRI: Raw Data Recording Rate

Function

This command sets the recording rate for all raw data logged
in the internal or external memory. This rate can be
independent of the data output rate on a serial port.

Command Format

Syntax

$PASHS,DRI,f[*cc]

Parameters

Example

Setting the recording rate to 5 seconds:

$PASHS,DRI,5*33

Relevant Query

Command

$PASHQ,DRI

See also

$PASHS,ATM

$PASHS,RAW

$PASHS,REC

$PASHS,POP

DST: Data Stream Connection Modes

Function

This command is used to set up the type of TCP/IP
connection to be implemented for each available data
stream.

Whereas $PASHS,BDS is used to define the type of data
available on each Ix port, the present command allows you to
define the conditions in which each available data stream can
be acquired from a remote equipment through an IP

Parameter

Description

Range

Default

s

Raw data recording rate.
Setting $PASHS,POP to “20”
is a prior condition to operat-
ing at 0.05 s (20 Hz).

0.05 sec or 0.1-0.4 sec
if the [F] option is acti-
vated.
0.5-0.9 s
1-999 s

1 s

*cc

Optional checksum

*00-*FF