Set Command Library

CPD,ARR,LEN: Setting the Baseline Length in Heading Mode

Function

This command is used to set the baseline length between the
base and the rover in heading mode.

Command Format

Syntax

$PASHS,CPD,ARR,LEN,f1[*cc]

Parameters

Example

Setting the baseline length to 2.5 meters:

$PASHS,CPD,ARR,LEN,2.5*21

Relevant Query

Commands

$PASHQ,CPD,ARR,LEN

$PASHQ,CPD

See Also

$PASHS,CPD,ARR,MOD

$PASHS,CPD,ARR,PAR

CPD,ARR,MOD: Enabling/Disabling the Heading Mode

Function

This command is used to enable or disable the heading mode
in the receiver. The heading mode is defined as a special RTK
mode primarily used when the receiver is mounted on a solid
body (e.g. a vehicle) and the baseline length is constant, to
determine the vehicle’s heading and pitch or roll.

Command Format

Syntax

$PASHS,CPD,ARR,MOD,s1[,c2][*cc]

Parameter

Description

Range

Default

f1

Baseline length in meters.
When setting f1 to”0” and the heading
mode is ON, the receiver switches to
calibration mode. Once the baseline
length is determined, the receiver
automatically switches from calibration
to heading operating mode.

0 or 0.05 to
1000 m

0

*cc

Optional checksum

*00-*FF

-