Rec: enable/disable, start/stop raw data recording, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 455: Relevant query command, See also

Advertising
background image

441

Set Command Library

REC: Enable/Disable, Start/Stop Raw Data Recording

Function

This command allows you to enable, disable, start or stop raw
data recording. Raw data is recorded in the memory you
selected with the $PASHS,MEM command.

Command Format

Syntax

$PASHS,REC,c[*cc]

Parameters

Examples

Starting raw data recording:

$PASHS,REC,Y*54

Stopping raw data recording:

$PASHS,REC,N*43

Relevant Query

Command

$PASHQ,REC

See also

$PASHS,MEM

$PASHS,ATM

Parameter

Description

Range

c

Control character:
• Y: Yes. The receiver will immediately start

recording data. This option also enables data
recording at receiver power-up, i.e. recording will
start every time you turn the receiver on, even if
you stopped recording before the end of the pre-
vious session.

• N: No. The receiver will immediately stop record-

ing data. This option also disables data recording
at receiver power up, i.e. the receiver won’t
resume data recording when you next turn it on.
This is the default mode.

• S: Stop. The receiver will immediately stop

recording raw data. This option does not affect
the way the receiver operates at power-up.

• R: Restart. The receiver will immediately start

recording raw data. This option does not affect
the way the receiver operates at power-up.

Y, N, S, R

*cc

Optional checksum

*00-*FF

Advertising