Radio transmitter – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 88

Advertising
background image

74

Using the Web Server

– Deleting a message definition can be done by simply

clicking on the corresponding “trash” sign in the

Clear

column on the far right. This deletes the table row.

– There is also a

Clear All button under the table that

allows you to delete all message definitions from the
table in one click.

• Click on the

Configure button to save all the changes made

and then go back to the

Base Setup menu

• Use one of the typical applications described below to

make the generated data available to users:

Radio transmitter

– Direct IP via modem

– Direct IP via Ethernet

– NTRIP server via modem

– NTRIP server via Ethernet

– RTK corrections delivered on port A, B or F

– Ethernet data streaming.

Radio Transmitter

• Click on

Base Setup > Transmitter and define the general

parameters of the base, as explained in section General

Parameters on page

68. Then proceed with the steps

below.

• Scroll down the page to display the Transmitter frame. In

the

Message field, select the type of differential data the

base will generate and the radio will transmit (ATOM,
RTCM, CMR, CMR+ or DBEN). Following your selection,

ProFlex 800

RTK Corrections

Serial Port

ProFlex 800

RTK Corrections

Radio

UHF Connector

External Radio

(Internal)

Advertising