Ntrip server via modem, Internet – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 93

Advertising
background image

79

Using the Web Server

Enable

Connect Now to allow the receiver to establish the

connection right after you have clicked on

Configure.

• In the corresponding

Differential Stream x pane, choose

Port= “P - Ethernet” as the output port delivering the
generated differential data. In the

Message field, choose

the type of differential message provided through this port
(ATOM, RTCM, CMR, CMR+ or DBEN).

NOTE: The receiver has been designed to offer two
separate and independent differential data outputs. Each
one can output a specific type of differential message. If
only one output is used, select

Port=“None” for the other

output.

• Click on the

Configure button to let the Web Server load all

your new parameters to the receiver. You have now
reached the end of the configuration phase.

NTRIP Server Via

Modem

CAREFUL: In the RTCM sense, an “NTRIP server” is a source
of corrections feeding an NTRIP caster (see RTCM paper
200-2004/SC104-ST
). But from the point of view of the
network terminology, an “NTRIP server” is a client, not a
server.

The internal modem should be configured first:

• Click on the

Connections menu and then on the Bluetooth/

Modem sub-menu.

• Set the following parameters in the

Internal Modem/Device

Settings pane:

Power: Select “On”. Then choose whether the modem
should be turned on automatically or manually:
Automatic: The modem will be switched on or off
automatically when the rover is respectively turned on
or off.
Manual: The modem will be powered up only by going
through the

Connections > Bluetooth/Modem page and

Modem

ProFlex 800

(Mobile Wireless
Communication)

Internet

(Client)

IP address
or server name

NTRIP Caster

Users