170

Web Server Help Files Collection

Meteorological

Unit

The Meteorological Unit page is used to set the conditions in
which the receiver will communicate with and get information
from the meteorological unit.

For each serial port (A, B, F), the following parameters can be
set to allow a connection to the meteorological unit:

“Update Now” but-
ton

Use this button to force the receiver to send
its IP address right away to the DynDNS
server.

DDN,SET

Parameter

Designation

$PASHS

Parameter

Designation

$PASHS

Process meteorological
unit

Enable this option to allow the
receiver to query the meteorological
unit, if connected to this port.

MET

Baud Rate

Set the port baud rate

PRT

Mode

Set the port mode (RS232 or RS422).
Only port A can be RS422 or RS232.
All the others are necessarily RS232.

MDP

RTS/CTS

Enable or disable the handshaking
protocol on this port.

CTS

Initialization string

Define the string used by the receiver
to initialize the meteorological unit, if
connected to this port.

MET

Trigger string

Define the string used by the receiver
to query the meteorological unit, if
connected to this port.

MET