Function, Command format, Relevant query command – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 472: See also

Advertising
background image

458

Set Command Library

SES,AUT: Setting a Series of Sessions Automatically

Function

This command is used to set a series of sessions through an
automatic procedure. Sessions will have similar duration and
common recording rate. They will take place one after the
other with no idle time in between.

Command Format

Syntax

$PASHS,SES,AUT,d1,d2,d3,f4[*cc]

Parameters

Comments

• The command is NAKed if the number of sessions

multiplied by the session duration is greater than 24
hours.

• The command will overwrite all the previously defined

sessions with the new ones.

Example

Setting 24 sessions of one hour each (continuous, round-the-
clock operation) with 1-second recording rate:

$PASHS,SES,AUT,000000,24,0100,1*6A

Relevant Query

Command

$PASHQ,SES

See Also

$PASHS,SES,PAR

$PASHS,SES,DEL

$PASHS,SES,AUT

Parameter

Description

Range

Default

d1

Session start time (hhmmss)

000000-235959

000000

d2

Number of sessions.

1-96

24

d3

Session duration (hhmm)

0005-2400

0100

f4

Data recording rate used during
sessions, in seconds.

0.05 or 0.1-0.4 if [F]
option activated.
0.5-0.9
1-999

30

*cc

Optional checksum

*00-*FF

Advertising