Receiver Description

that the 12 V DC will be available only when the receiver is
powered from and external source, and not solely from its
internal battery.

On port A, the 1PPS output is similar to a standard TTL
output (0/+5 V):

• VOH Min= 4.5 V at IOL = - 4 mA

• VOH Max= 0.4 V at IOL= - 4 mA

Port B consists of the following:

• 1 x RS232 output, electrically similar to that on port A

• 1 x Event input with the following characteristics:

VIH Min = 3.7 V

• VIL Max = 1.6 V

Port F provides an RS232 interface, electrically similar to
that on port A.

Multi-Function

Serial Cable

In the basic supply of the ProFlex 800 CORS station, this
cable (P/N 702450) comes with bare wires at one end.

It is also available as an optional cable (P/N 702443) with a
DB15 standard connector instead of bare wires.

The pinout of each of these cables is given below.

Cable P/N 702450, length: 2.90 m

Cable P/N 702443, length: 0.25 m

1

2

3

4

5

6

7

Shield

(RS232 / RS422)

Yellow

Pink

Gray

Green

Blue

Brown

White

Black

Case

RTS / TXD+

TXD / TXD-

RXD / RXD+

CTS / RXD-

GND

+12 V DC

Event / 1PPS

Fischer S102-A056

or equivalent