Relevant query command, See also, Pps: setting pps pulse properties – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 437: Function, Command format

Advertising
background image

423

Set Command Library

$PASHS,POS,3722.2912135,N,12159.7998217,W,15.25*1F

Relevant Query

Command

$PASHQ,CPD,POS

See also

$PASHS,CPD,MOD,BAS

$PASHS,ANH

$PASHS,ANR

PPS: Setting PPS Pulse Properties

Function

This command is used to set the period, offset and GPS
synchronized edge (rising or falling) of the PPS pulse.

Command Format

Syntax

$PASHS,PPS,f1,f2,c3[*cc]

Parameters

Example

Setting the PPS signal to a period of 2 seconds, with an offset
of 500 ms and a GPS-synchronized rising edge:

$PASHS,PPS,2,+500,R*74

Relevant Query

Command

$PASHQ,PPS

See Also

$PASHS,NME (PTT)

Parameter

Description

Range

Default

f1

PPS time period, a multiple or
fraction of 1 second.
• 0: 1 PPS disabled

0 to 1, with 0.1-sec
increments1 to 60,
with 1-sec incre-
ments

0

f2

Time offset in milliseconds.

± 999.9999

0

c3

GPS-synchronized edge code:
• “R” for rising edge
• “F” for falling edge

R, F

R

*cc

Optional checksum

*00-*FF

Advertising