Spectra Precision ProFlex 800 Reference Manual User Manual

Page 336

Advertising
background image

322

Set Command Library

Parameters

ATOM Messages:

ATOM PVT messages contain the following sub-blocks: COO,
ERR, VEL, CLK, LCY, HPR, BLN, MIS, PRR and SVS.

DAT messages are generated every time a new frame is
decoded.

Parameter

Description

Range

s1

ATOM message type

PVT, ATR, NAV, DAT, EVT,
RNX. See table below.

c2

• Port routing the ATOM mes-

sage:A, B, F: Serial portC: Blue-
tooth port

• E: Modem
• I, I1-I9: Ethernet port
• M, U: Internal memory (U), USB

key (U)

• R: Automatic recording session

(internal or external memory)

A, B, C, E, F, I, M, R, U, I1-
I9

s3

Enable (ON) or disable (OFF) this
ATOM message type.

ON, OFF

f4

Output rate, in seconds.(Default
value is specific to each message
type.)

0.05 or 0.1-0.4 sec with [F]
option activated.
0.5-0.9 s
1-999 s

*cc

Optional checksum

*00-*FF

Data

ATOM

Number

Description

Default

Output

Status on

Ports A, B, F,

I, I1-I9, E

Default Output

Status on Ports

M, U and R

PVT

4095,3

Positioning results

OFF

OFF

ATR

4095,4

Receiver attributes

OFF

ON

NAV

4095,5

GNSS navigation data

OFF

ON, at 300 sec-
onds

DAT

4095,6

Raw GNSS data
(DAT,FRM)

OFF

OFF
(no output rate)

EVT

4095,14 Event

OFF

OFF

RNX

4095,7
Sce-
nario 0

GNSS raw measuremenst OFF

ON, at 1 second