Relevant set command, See also – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 526

Advertising
background image

512

Query Command Library

Relevant Set

Command

$PASHS,ATM

See also

$PASHQ,ATM

$PASHQ,ATO

SIT

Site ID

4 characters

REC

Data recording:
• Y: Data recording enabled
• N: Data recording disabled
• S: Data recording enabled but stopped

Y, N, S

MEM

Selected memory:
• M: Internal memory
• U: USB memory

M, U

ANH

Antenna height

0.000-99.999

ANT

Height measurement type (slant/vertical)

SLANT, VERT

ANR

Antenna reduction mode

ON, OFF, ARP

ATOM

ATOM message type

PVT, ATR, NAV, DAT,
EVT, RNX

PRTA
PRTB
PRTF

Labels for serial ports A, B and F

ON, OFF

PRTC

Label for Bluetooth

ON, OFF

PRTE

Label for Modem

ON, OFF

PRTI

Label for Ethernet

ON, OFF

MEMM
MEMU
MEMR

Labels for memories M, U and R

ON, OFF

I1-I9

Data streaming port

ON, OFF

BAUD

If serial port used, then baud rate
If memory used, “0” if not available, else “1”

0-15 (see table
below)

Code

Baud Rate

Code

Baud Rate

0

300

8

57600

1

600

9

115200

2

1200

10

230400

3

2400

11

480600

4

4800

12

921600

5

9600

13

1428571

6

19200

14

2500000

7

38400

15

5000000

Parameter

Description

Range

Advertising