Met,par: setting the meteorological unit, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 418: Relevant query command

Advertising
background image

404

Set Command Library

MET,PAR: Setting the Meteorological Unit

Function

This command is used to define all the parameters needed to
communicate with the meteorological unit.

Following the execution of this command, and then that of
$PASHS,OUT,x,MET,ON, the receiver will regularly query the
meteorological unit by sending the trigger string every x
seconds of query interval.

Command Format

Syntax

$PASHS,MET,PAR,c1,s2,s3,d4[*cc]

Parameters

Comments

• This command overwrites all the settings previously

performed with the following commands:

$PASHS,MET,INIT

– $PASHS,MET,INTVL

– $PASHS,MET,CMD

• In fact, the $PASHS,MET,PAR command is used for the

same purpose as, and is more convenient than, the above
three commands, which are maintained only for the sake
of compatibility with the Ashtech iCGRS reference station.

Example

Setting the meteorological unit:

$PASHS,MET,PAR,A,*9900ID,*0100P9,5*57

Relevant Query

Command

$PASHQ,MET

Parameter

Description

Range

Default

c1

Receiver serial port connected to
the meteorological unit.

A, B, F

s2

Initialization string

20 characters max.

s3

Trigger string

20 characters max.

d4

Query interval, in seconds. “0”
means no query.

0; 5-9999

5

*cc

Optional checksum

*00-*FF

Advertising