Relevant query command, See also – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 443

Advertising
background image

429

Set Command Library

Examples

Enabling output of MPC message type on port A to 1 second:

$PASHS,RAW,MPC,A,ON,1*1E

Enabling output of SNV message type on port A to 300
seconds:

$PASHS,RAW,SNV,A,ON,300*09

Comments

• For each of the SNV, SNG, SNW, SAL, SAG, SAW and ION

messages, the f4 parameter can only take an integer value
of seconds and refers to the interval between messages
related to the same satellite and with the same content.

For a given satellite, each of these messages is therefore
renewed every x seconds (where x=f4), or following a
change in the message content (“on change”), whichever
occurs first.

Each of these messages cannot be output more than once
over a given period of 1 second.

• By default, f4 is set as follows:

• The SBD message output rate is always 1 second (as

decoded). Parameter f4 is ignored.

Relevant Query

Command

$PASHQ,RAW

$PASHQ,RWO

See also

$PASHS,RAW,PER

$PASHS,RAW,ALL

$PASHS,POP

SBD

SBAS data message

Output message

f4 Default Value

SNV, SNG, ION

900

SAL, SAG

3600

SNW

120

SAW

300

Data

Description