Function, Command format, Relevant query command – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 496: See also

Advertising
background image

482

Set Command Library

TLT,INIT: Defining the String Used to Initialize the Tiltmeter

Function

This command is used to define the character string that will
initialize the tiltmeter. The command also specifies the ID of
the receiver port used to communicate with the tiltmeter.

The initializing string is in the form “*xxxxxx”. There is no
initialization string defined by default.

Command Format

Syntax

$PASHS,TLT,INIT,c1,s2[*cc]

Parameters

Example

Setting initialization string to “*9900ID”, tiltmeter
connected to port F:

$PASHS,TLT,INIT,F,9900ID*44

Relevant Query

Command

$PASHQ,TLT

See Also

$PASHS,TLT,CMD

$PASHS,TLT,INTVL

$PASHS,OUT,x,TLT

Parameter

Description

Range

c1

Receiver serial port connected to the tiltmeter. A, B, F

s2

Initialization string (not including the leading
“*” character)

20 characters max.

*cc

Optional checksum

*00-*FF