446

Set Command Library

Command Format

Syntax

$PASHS,RNX,TYP,d1,d2[,d3][*cc]

Parameters

Parameter

Description

Range

Default

d1

Scenario number

See table below

4

d2

Output rate for observa-
tions, in seconds.

0.1-0.4 if [F] option activated.
0.5-0.9
1-1800

1

d3

Output rate for attributes
(receiver and antenna
names), in seconds.

0:Disabled
1-1800

31

*cc

Optional checksum

*00-*FF

Scenario

Number

Description

0

All available raw data in full presentation, full computed reference
position follows at each epoch. This scenario is not recommended
for use as differential protocol
.

1

L1 pseudo-range and carrier phase in full presentation, extended
fixed position follows each 12 epochs.

2

L1 SNR, pseudo-range and carrier phase in full presentation,
extended fixed position follows each 12 epochs.

3

L1&L2 pseudo-range and carrier phase in full presentation, extended
fixed position follows each 12 epochs.

4

L1 &L2 SNR, pseudo-range and carrier phase in full presentation,
extended fixed position follows each 12 epochs.

100

L1&L2 compact pseudo-range and full carrier phase, extended fixed
position follows each 12 epochs, all the data are decimated in 5 times
compared to L1 carrier phase.

101

L1&L2 compact pseudo-range and compact carrier phase, extended
fixed position follows every 12 epochs, all the data are decimated in 5
times compared to L1 carrier phase. This scenario cannot be used
with a moving receiver
.

201

Same as scenario 1, but extended computed reference position fol-
lows each epoch.

202

Same as scenario 2, but extended computed reference position fol-
lows each epoch.

203

Same as scenario 3, but extended computed reference position fol-
lows each epoch.

204

Same as scenario 4, but extended computed reference position fol-
lows each epoch.

Advertising