626

Query Command Library

See also

$PASHS,RTC,TYP

RWO: Raw Data Output Settings

Function

This command is used to query the raw data output
parameters on the specified port.

Command Format

Syntax

$PASHQ,RWO,c[*cc]

Parameters

Response Format

Syntax

$PASHR,RWO,c1,d2,f3,d4,n(s5,f6,c7)*cc
Where n=8

Parameters

Parameter

Description

Range

c

Port ID the command refers to

A, B, C, F, I, M, R, U,
I1-I9

*cc

Optional checksum

*00-*FF

Parameter

Description

Range

c1

The port ID specified in the command is
reminded in this field:
• A, B, F: Serial port
• C: Bluetooth port
• I, I1-I9: Ethernet port
• M, U: Memory
• R: Automatic record session (internal

or external memory)

A, B, C, F, I, M, R, U,
I1-I9

d2

Baud rate code for serial port.
For other devices, “0” if not available, else
“1”

0-9 (A, B, F). See
table below
0-1 (C, M, U, R, I)

f3

Output rate defined by the last
$PASHS,RAW,PER command run

0-999.9

d4

Number of raw data messages

11

s5

Raw data message types

MPC, DPC, PBN,
SNV, SNG, SNW,
SAL, SAG, SAW,
ION, SBD

f6

Output rate
0: Message disabled

0-999.00