Spectra Precision ProFlex 800 Reference Manual User Manual

Page 166

Advertising
background image

152

Web Server Help Files Collection

Rover

Use this area to specify the position computation mode used
as well as the type of base the rover will be working from.

Antenna

Use this area to define the parameters of the antenna used
physically at the rover, as well as a virtual antenna if
necessary. A virtual antenna may be defined to allow the rover
to deliver raw data as if those were collected with this
antenna.

Parameter

Designation

$PASHS

Ambiguity Fix-
ing

Define the confidence level required of every RTK
solution to be valid. The possible choices are:
• 0: The rover will stay in “Flying RTK” mode (float

mode) once this type of solution is obtained
(RTK solution never delivered).

• 95.0: 95% of the measurements need to pass

the internal quality tests.

• 99.0: 99% of the measurements need to pass

the internal quality tests.

• 99.9: 99.9% of the measurements need to pass

the internal quality tests.

CPD,AFP

Fast RTK

Set this option as follows:
• Check it to enable Fast RTK.
• Clear it to disable Fast RTK.

CPD,FST

Moving Base

Keep this box cleared for a rover using a static
base, check it if the rover will be working from a
moving base.
Enabling the Moving Base option will clear the Fast
RTK option if it was enabled previously.

CPD,MOD

Dynamic

Choose the dynamic model that best suits the
rover motion.

DYN

Parameter

Designation

$PASHS

Reference
Position

Select one of the options below to define the ref-
erence location of the antenna:
• L1 phase center
• Antenna Reference Point (ARP)
• Ground mark

ANR

Measurement
Type

Specify the type of measurement (“Slant” or “Ver-
tical”) through which the above antenna height
was measured.

ANH

Antenna
Height

Enter the measured antenna height according to
the measurement type used and the selected dis-
tance unit.

ANT or ANH