Set Command Library

DEL,d7

G-file deletion:
• 0: Keep G-file after RINEX conversion
• 1: Delete G-file after RINEX conversion

0-1

1

MOV,d8

File moved to subdirectory:
• 0: No move
• 1: Move converted files only
• 2: Move original and converted files

0-2

1

DST,d9

Memory where to move the files:
• 0: Internal memory
• 2: USB key

0, 2

0

PTH,s10

Format of the subdirectory where files are
moved (see comments below).

Y/D

FTP,d11

Automatic FTP transfer
• 0: No transfer
• 1: Automatic transfer to FTP server
• 2: Automatic transfer to FTP server, fol-

lowed by deletion of the file if d8=1 or 2

See $PASHS,SES,FTP,PAR for FTP settings.

0, 1, 2

0

RFM,c12

Ring file memory management:
• N (No): Sessions stopped when memory

full

• Y (Yes): Oldest file removed when free

memory is less than 15 Mbytes.

Y, N

N

SLP,c13

Enable/disable sleep mode:
• No: The receiver won’t be powered off

between sessions

• Yes: The receiver will be powered off

between sessions. Power will be restored
automatically 15 minutes before the next
session starts.

Y, N

N

GLO,s14

GLONASS data conversion:
• ON: GLONASS measurements will be con-

verted.

• OFF: GLONASS measurements will not be

converted.

ON, OFF

ON

SBA,s15

SBAS data conversion:
• ON: SBAS measurements will be con-

verted.

• OFF: SBAS measurements will not be con-

verted.

ON, OFF

ON

GAL,s16

GALILEO data conversion:
• ON: GALILEO measurements will be con-

verted.

• OFF: GALILEO measurements will not be

converted.

ON, OFF

ON

PER,d17

Period of RINEX measurements, in seconds.
“0” means the period used is the same as
that used in the G-file.

0-60

0