Comments, Relevant query command, See also – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 333

Advertising
background image

319

Set Command Library

Parameters

Examples

Entering the vertical measurement (2 m) of a rover antenna:

$PASHS,ANT,0,0,2.000*2E

Entering the slant measurement (1.543 m) of the
MAG111406 antenna used at a base:

$PASHS,ANT,1.543,0.0921,-0.0516*0A

Comments

• The vertical height from ARP to ground mark can also be

entered through the ANT command, which in this case
should be used as follows:

Set f1 and f2 to “0.0”

– Enter the antenna height from ARP to ground mark as

f3. Only when f1=f2=0.0 can you define f3 this way.

f3 is negative when the ARP is below the SHMP.

• When you enter an antenna height greater than 6.553 m

(see f1 and f2 above), be aware this will NOT be the value
of antenna height broadcast through RTCM messages and
the one saved to the G-file. Instead, a fixed value of 6.553
meters will be provided.

Relevant Query

Command

$PASHQ,ANT

See Also

$PASHS,ANH

$PASHS,ANR

Parameter

Description

Range

f1

Slant height measurement, from ground
mark (GM) to antenna edge (SHMP).

0-6.553 m
6.553-100 m

f2

Antenna radius: horizontal distance from the
geometrical center to the antenna edge.

0-6.553 m

f3

Vertical offset:
• From ARP to SHMP, if radius and slant

height are not null.

• From Ground Mark to ARP, if radius and

slant height are null.

0 to ±6.553 m
6.553-100 m

*cc

Optional checksum

*00-*FF

Advertising