See also, Tlt: tiltmeter setup, Function – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 661: Command format, Response format

Advertising
background image

647

Query Command Library

Parameters

Example

$PASHQ,TCP
$PASHR,TCP,MOD=1,LGN=Magellan,PWD=u6huz8,ADD=192.34.76.1,
PRT=8888*7A

See Also

$PASHS,TCP,PAR

$PASHS,ETH,PAR

TLT: Tiltmeter Setup

Function

This command is used to query the tiltmeter for its setup
data.

Command Format

Syntax

$PASHQ,TLT[*cc]

Parameters

None.

Response Format

Syntax

Through an example:

$PASHQ,TLT
TILTMETER PARAMETERS SETTINGS
PRTA:OFF INIT_STR:NO TRIG_CMD:*0100P9 INTVL:0005
PRTB:OFF INIT_STR:NO TRIG_CMD:*0100P9 INTVL:0005
PRTF:OFF INIT_STR:NO TRIG_CMD:*0100P9 INTVL:0005

See Also

$PASHS,TLT,CMD

Parameter

Description

Range

s1

TCP/IP connection mode:
• 0: Disabled
• 1: Enabled with authentication
• 2: Enabled without authentication (default)

0-2

s2

Login

32 characters max.

s3

Password

32 characters max.

s4

IP address

0.0.0.0-
255.255.255.255

d5

Port number

0-655535

*cc

Checksum

*00-*FF