See also, Tlt: tiltmeter setup, Function – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 661: Command format, Response format
647
Query Command Library
Parameters
Example
$PASHQ,TCP
$PASHR,TCP,MOD=1,LGN=Magellan,PWD=u6huz8,ADD=192.34.76.1,
PRT=8888*7A
See Also
$PASHS,TCP,PAR
$PASHS,ETH,PAR
TLT: Tiltmeter Setup
Function
This command is used to query the tiltmeter for its setup
data.
Command Format
Syntax
$PASHQ,TLT[*cc]
Parameters
None.
Response Format
Syntax
Through an example:
$PASHQ,TLT
TILTMETER PARAMETERS SETTINGS
PRTA:OFF INIT_STR:NO TRIG_CMD:*0100P9 INTVL:0005
PRTB:OFF INIT_STR:NO TRIG_CMD:*0100P9 INTVL:0005
PRTF:OFF INIT_STR:NO TRIG_CMD:*0100P9 INTVL:0005
See Also
$PASHS,TLT,CMD
Parameter
Description
Range
s1
TCP/IP connection mode:
• 0: Disabled
• 1: Enabled with authentication
• 2: Enabled without authentication (default)
0-2
s2
Login
32 characters max.
s3
Password
32 characters max.
s4
IP address
0.0.0.0-
255.255.255.255
d5
Port number
0-655535
*cc
Checksum
*00-*FF