Relevant query command, See also, Function – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 423: Command format
409
Set Command Library
Parameters
Example
Setting the output rate to 1 second:
$PASHS,NME,PER,1*45
Relevant Query
Command
$PASHQ,NMO
See also
$PASHS,NME
$PASHS,POP
NPT: Tagging SBAS Differential Positions in NMEA & NMEA-Like
Messages
Function
This command allows you to define the code the receiver will
insert in each of its NMEA-like or NMEA messages to tell that
the position solution inserted in the message is of the SBAS
Differential type.
Command Format
Syntax
$PASHS,NPT,d1,d2[*cc]
Parameters
Parameter
Description
Range
Default
f
Output rate.
Setting $PASHS,POP to “20”
is a prior condition to operat-
ing at 0.05 s (20 Hz).
0.05 s or 0.1-0.4 s with
[F] option activated.
0.5-0.9 s
1-999 s
1 s
*cc
Optional checksum
*00-*FF
Parameter
Description
Range Default
d1
Code assigned to SBAS differential position
solution in NMEA-like messages (CRT, DCR,
DPO, POS, VEC):
• 0: Code “1”
• 1: Code “9”
0,1
0