Out,x,met: starting meteo data acquisition, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual
Page 430: Relevant query command, See also
416
Set Command Library
OUT,x,MET: Starting Meteo Data Acquisition
Function
This command is used to start the data processing in the
meteorological unit. The command also specifies the ID of
the receiver port used to communicate with the
meteorological unit.
By executing the command, the meteorological unit is first
initialized, and then the receiver is allowed to send queries at
regular intervals of time, based on the preset value of query
interval.
Command Format
Syntax
$PASHS,OUT,c1,MET,s2[*cc]
Parameters
Example
Starting the meteorological unit connected to port A:
$PASHS,OUT,A,MET,ON*0B
Relevant Query
Command
$PASHQ,MET
See Also
$PASHS,MET,CMD
$PASHS,MET,INIT
$PASHS,MET,PAR
$PASHS,MET,INTVL
Parameter
Description
Range
c1
Receiver serial port connected to the meteorological unit. A, B, F
s2
Enable/disable processing in meteorological unit
ON, OFF
*cc
Optional checksum
*00-*FF