Out,x,met: starting meteo data acquisition, Function, Command format – Spectra Precision ProFlex 800 Reference Manual User Manual

Page 430: Relevant query command, See also

Advertising
background image

416

Set Command Library

OUT,x,MET: Starting Meteo Data Acquisition

Function

This command is used to start the data processing in the
meteorological unit. The command also specifies the ID of
the receiver port used to communicate with the
meteorological unit.

By executing the command, the meteorological unit is first
initialized, and then the receiver is allowed to send queries at
regular intervals of time, based on the preset value of query
interval.

Command Format

Syntax

$PASHS,OUT,c1,MET,s2[*cc]

Parameters

Example

Starting the meteorological unit connected to port A:

$PASHS,OUT,A,MET,ON*0B

Relevant Query

Command

$PASHQ,MET

See Also

$PASHS,MET,CMD

$PASHS,MET,INIT

$PASHS,MET,PAR

$PASHS,MET,INTVL

Parameter

Description

Range

c1

Receiver serial port connected to the meteorological unit. A, B, F

s2

Enable/disable processing in meteorological unit

ON, OFF

*cc

Optional checksum

*00-*FF

Advertising